OSI/FTAM Programming Reference Manual

NonStop FTAM Initiator Error Messages
HP NonStop OSI/FTAM Programming Reference Manual528611-001
B-34
FTAM Initiator Error Codes
-6039
Cause. Cause. An internal ACSE confirm (A-ASSOCIATE) was received without user
data. Normally, the user data of the A-ASSOCIATE confirm would contain the
FINITIALIZE confirm. This error indicates a problem with the responding entity on the
remote system.
Subcodes. None.
Effect. The initiator rejects your request.
Recovery. Call the APS_DISCARD_ procedure to discard the association context.
Determine the cause of the failure by tracing the FTAM initiator, TAPS process, or both
processes. Also, investigate the remote system to which the initialize request was sent.
A problem with OSI addresses or configuration on that system might be causing this
error. Fix the problem and then rerun the application.
ZFTM-ERR-EMPTY-ASSOC-CNF