OSI/MHS Management Programming Manual
Event Messages
OSI/MHS Management Programming Manual—424824-001
6-99
25: ZMHS-EVT-FTL-OSI-RESOURCE
ZMHS-TKN-FIRST-SUBCODE
further describes ZMHS-TKN-FIRST-ERROR. It is only present if the token 
ZMHS-TKN-ERROR-DATA has the value ZSPI-VAL-TRUE.
ZMHS-TKN-DEVICE-DATA
has the value ZSPI-VAL-TRUE if the device information is present, ZSPI-VAL-
FALSE if the device info is not present.
ZMHS-TKN-FSYS-ERROR
is only present if the token ZMHS-TKN-DEVICE-DATA has a value of ZSPI-VAL-
TRUE.  It is the file system error code that was received by X25AM or TLAM, 
whichever is being used to provide the lower comm layers.
ZMHS-TKN-CONNECT-INFO
is only present if the token ZMHS-TKN-DEVICE-DATA has a value of ZSPI-VAL-
TRUE. It has the value ZMHS-VAL-CONNECT-INFO-X25 if the error occurred on 
an X25 connection, ZMHS-VAL-CONNECT-INFO-LAN if the error occurred on a 
LAN connection.
ZMHS-TKN-X25-DATA
has the value ZSPI-VAL-TRUE if the X25 error information is present, ZSPI-VAL-
FALSE if the X25 error information is not present. It is only true if the lower 
comms level is provided by X25AM.
ZMHS-TKN-X25-DISC-REASON1 ... 4
are only present if ZMHS-TKN-X25-DATA has a value of ZSPI-VAL-TRUE.  They 
are the reasons for the circuit disconnection as returned by APS_STATUS in the 
structure ZAPS-DDL-LL-BUFFER. For further details see the OSI/AS 
Programming Manual.
ZMHS-TKN-X25-CLEAR-CAUSE
is only present if ZMHS-TKN-X25-DATA has a value of ZSPI-VAL-TRUE. It 
species the clear cause. For further details see the OSI/AS Programming Manual.
ZMHS-TKN-X25-DIAG-CODE
The ZMHS-TKN-DIAG-CODE token is only present if ZMHS-TKN-X25-DATA 
has a value of ZSPI-VAL-TRUE. It specifies the diagnostic code. For further details 
see the OSI/AS Programming Manual.
Cause. This event indicates that a resource problem exists for the named device or the 
OSI services as a whole at the start up of an OSI/MHS GROUP. No retry attempts are 
made and the process stops.
Recovery. Ensure that the device name specified in the event message is correctly 
configured.  Restart the group.