OSI/MHS Management Programming Manual

Event Messages
OSI/MHS Management Programming Manual424824-001
6-121
32: ZMHS-EVT-NO-MTA-PW-SVR
32: ZMHS-EVT-NO-MTA-PW-SVR
The MTA bind password server was configured for an adjacent MTA and an attempt is
made to establish an association with the adjacent MTA, but no MTA bind password
server was configured. This is not a critical event.
Token Descriptions
ZCOM-TKN-OBJNAME
is the name of the object referred to in the event.
ZEMS-TKN-EMPHASIS
has the value ZSPI-VAL-FALSE, indicating that this is not a critical event.
ZEMS-TKN-CONSOLE-PRINT
has the value ZSPI-VAL-TRUE.
Cause. An attempt was made to use a message transfer agent (MTA) bind password
server, but no password server has been specified in the configuration. Attempts to
establish outgoing associations with the adjacent MTA are abandoned. Incoming
associations from the adjacent MTA are rejected.
Recovery. Define an MTA bind password server process for the OSI/MHS subsystem,
or change the MTA bind password server to OFF for the adjacent MTA.
Considerations
OSI/MHS MRP processes can generate this event message.
This event message is reported to the primary collector.
Additional Unconditional Tokens
ZCOM-TKN-OBJNAME <1> token-type ZSPI-TYP-STRING.
ZEMS-TKN-EMPHASIS token-type ZSPI-TYP-BOOLEAN.
ZEMS-TKN-CONSOLE-PRINT token-type ZSPI-TYP-BOOLEAN.
Event-Message Text
No MTA Password Server configured for <1>