OSI/TS Management Programming Manual

ALTER SERVICE Command
Commands and Responses
056786 Tandem Computers Incorporated 5–43
provided. If you do not supply a value, the SYSGEN value of the X25AM line
is used. The SYSGEN default value of X25AM is 4 (for both integers).
375
4 150
5 300
6 600
7 1200
8 2400
9 4800
10 9600
11 19200
12 48000
Note that these values are based on the CCITT X.25 recommendations for 1980
and 1984.
ZESIS-ENABLE
controls the ES-IS protocol. If set to ZSPI-VAL-TRUE, the protocol is enabled;
if set to ZSPI-VAL-FALSE, the protocol is disabled. The default value is ZSPI-
VAL-TRUE.
ZESIS-ES-CONF-TIME
is the length of the interval at which the protocol must report its configuration
to the subnetwork. This field is applicable only if ZESIS-ENABLE is set to
ZSPI-VAL-TRUE. The interval is expressed in hundredths of a second (0.01
seconds per increment), rounded down to the nearest second. The values
range from 100 (1 second) through 65500 (655 seconds). The default value is
500 (5 seconds).
ZESIS-ES-GROUP-MAC-ADDR
is the MAC station group address used by all the OSI end systems in the
network. This field is applicable only if ZESIS-ENABLE is set to ZSPI-VAL-
TRUE. The address is expressed as a string of hexadecimal digits, having a
maximum length of 12 digits. To reset this field to its default value, set the
first byte to ZOS4-VAL-ADDR-RESET-BYTE. The default value is
09002B000004.
ZESIS-IS-GROUP-MAC-ADDR
is the MAC station group address used by all the OSI intermediate systems in
the network. This field is applicable only if ZESIS-ENABLE is set to ZSPI-
VAL-TRUE. The address is expressed as a string of hexadecimal digits,
having a maximum length of 12 digits. To reset this field to its default value
set the first byte to ZOS4-VAL-ADDR-RESET-BYTE. The default value is