OSI/TS Management Programming Manual

Event-Message Descriptions
Event Messages
056786 Tandem Computers Incorporated 6–25
309: ZOS4-EVT-ACCESS-
ERR
This is not a critical event. The OSI/TS subsystem issues this message when it cannot
access an NSP subdevice (X25AM or TLAM) or a DSM server (such as $ZNET). Any
transport connections that have been established over the indicated NSP subdevice
will be disconnected.
Unconditional Tokens
ZEMS-TKN-EMPHASIS token-type ZSPI-TYP-BOOLEAN.
ZEMS-TKN-CONSOLE-PRINT token-type ZSPI-TYP-BOOLEAN.
ZCOM-TKN-SUBJ-PROC token-type ZSPI-TYP-CRTPID.
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST.
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR.
ZSPI-TKN-PROC-ERR token-type ZSPI-TYP-ENUM.
ZSPI-TKN-FUNCTION token-type ZSPI-TYP-ENUM.
ZFIL-TKN-FILENAME token-type ZSPI-TYP-FNAME.
ZFIL-TKN-XFILENAME token-type ZSPI-TYP-STRING.
ZSI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL.
Event-Message Text
process-name
, File
filename
Cannot Be Accessed -
Guardian Error=
error
,
Using Procedure { CONTROL [, Function=
function
] }
{ OPEN }
{ READ }
{ SETMODE [, Function=
function
] }
{ WRITE }
{ WRITEREAD }
Token Descriptions
ZEMS-TKN-EMPHASIS
has the value ZSPI-VAL-FALSE, indicating that this is not a critical event.
ZEMS-TKN-CONSOLE-PRINT
has the value ZSPI-VAL-TRUE, indicating that the EMS compatibility distributor
will route the event message to the designated operator console.
ZCOM-TKN-SUBJ-PROC
is the name of the TSP process that caused the event. It is the subject of the
message.
ZSPI-TKN-ERRLIST and ZSPI-TKN-ENDLIST
enclose a standard SPI error list, as described in the Distributed Systems
Management (DSM) Programming Manual. The contents of this error list provide
information about the file-system error that occurred.