OSM Migration Guide (G06.26+)

OSM Server-Based Components
OSM Migration Guide527273-010
3-4
Configuring Automatic Data Collection
Configuring Automatic Data Collection
OSM version T0682 AAC has enhanced automatic data collection capabilities. If
enabled, OSM automatically collects diagnostic data whenever a hardware failure
causes a Problem Incident Report (IR) to be created.
Automatic data collection is enabled by an OSM Service Connection system-level
action (Enable/Disable Automation of Data Collection), and is configured through a
combination of OSMCONF file settings and Service Connection actions. You can copy
the following settings from the OSMINI file included with T0682 AAC into your existing
OSMCONF file. (To create an OSMCONF file from the OSMINI, or to put OSM
configuration file changes into effect when OSM processes are already running, see
Creating and Using an OSMCONF File.)
The following data collection configuration is now done through OSM Service
Connection actions (under the System object) rather than OSMCONF file settings:
Set Data Collection Volume – specifies a volume in which to collect diagnostic
data. The default volume is $SYSTEM.
Set Days to persist for Diagnostic Data – specifies how long the data files remain in
the collection volume before they are automatically deleted (default is 28 days).
The current automatic data collection settings are displayed as System object
attributes, under the “Data Collection Services” heading (on the Attributes tab):
Automatic Data Collection State (Enabled or Disabled)
Diagnostic Data Collection Volume
Days to Persist Collected Diagnostic Data
ADC-related
OSMCONF Parameters Purpose/Effect
Possible
Values Default
AdcDelayTimeInMin
Delay time (in minutes) between the time
that the initial Problem IR is received and
data collection begins. The purpose is to
conduct a single data collection for all
related Problem IRs.
5 to 60 15
AdcEventTimeinHrs
Time (in hours), prior to when the Problem
IR is generated, that the data collection will
collect EMS events from $ZLOG and $0.
1 to 60 12
EnableNDData
Enables ability to send a Diagnostic Data IR
to the OSM Notification Director. (Not visible
in OSM ND version T0632 AAK; however,
Problem IRs also provide the location of
collected data files in ZZAA alarm details.)
ON/OFF ON
AdcFilColTimeinMin
Specifies the time period (in minutes), after
the initial Problem IR is created, that ZZAA
and ZZPS files will be collected.
5 to 120 5
Note. Previous OSMCONF settings to ENABLE_ADC, specify ADC_PAKVOL, or