OSM Service Connection User's Guide (G06.30+)

Rack Name
A user-defined name assigned to identify the rack in which the FCDM is
located.
Rack Offset
A number (from 1 to 42) assigned to describe the location of the FCDM
within the rack.
Locator
An optional text string assigned to further identify the physical location of
the FCDM.
This attribute is displayed only if a value is specified using the Set Physical
Location action.
Alarm Panel Identifier
For Telco systems only.
Displays the system alarm panel (SAP) identifier for this hardware resource,
as specified through the Alarm Panel Identifier option within the Set
Physical Location action. This attribute is displayed only if a value is
specied through the action.
Logical
Vendor Product ID
The product identifier of the component assigned to it by the supplier of
the component.
Vendor Product Revision
A code that identifies the generation of the component. Assigned by the
supplier of the component.
World Wide Name A unique, 64-bit number assigned to the hardware ports.
Path B
Configured Controller Location
The location of FCSA connected to the disk drive through Port B.
Example: FCSA.FSAC-1.GRP-111.MOD-2.SLOT-1
Fibre Channel Controller
Identifies the FCSA FSAC connected to the FCDM through Port B.
Example: FCSA FSAC (111.2.1.1)
Path A
Configured Controller
Location
The location of FCSA connected to the disk drive through Port A.
Example: FCSA.FSAC-1.GRP-111.MOD-2.SLOT-1
Fibre Channel Controller
Identifies the FCSA FSAC connected to the FCDM through Port A.
Example: FCSA FSAC (111.2.1.1)
Actions
Blink All LEDs Off
Turns off the blinking of the fault LEDs on the FCDM, disks, FC-AL I/O module, power supplies,