OSM Service Connection User's Guide (G06.30+)

FXSA / FX2SA (ServerNet/FX / ServerNet/FX2)
Attributes
Actions
The ServerNet/FX adapter (FXSA) and ServerNet/FX 2 adapter (FX2SA) field-replaceable units
(FRUs) allow NonStop S-series servers to communicate with NonStop K-series servers using a
fiber-optic ring.
Location in OSM Tree: System > Group > Module > FX2SA
Slot Location: FXSA and FX2SA FRUs can be installed in slots 51 through 54 in PMF or IOMF
enclosures (service side).
Attributes
FX2SA
Service State
Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK. Values
Physical
Hardware Revision
A code that identifies the generation of the component. Hardware revision
codes are used for tracking components.
Manufacturer Identifies the manufacturer of the component.
Part Number
The part number of the component that was assigned in manufacturing. Use
part numbers for identifying and ordering parts.
Power State
Whether the component is powered on. Values
Track ID
A unique serial number that identifies the component. Track IDs are used for
tracking components.
Logical
Right Squelch Detected
Indication of whether the carrier level is detected by the receiver
from the right direction:
True:S quelch is detected, meaning that the carrier signal cannot
be received.
False: Squelch is not detected, meaning that the carrier signal can
be received.
Unknown: Status or type of signal being received is unknown.
FOX Cluster Number
An integer, between 1 and 14, that identifies the node to which the
ServerNet/FX or ServerNet/FX2 adapter field-replaceable unit
(FRU) is connected.