OSM Service Connection User's Guide (G06.30+)

the ServerNet/FX or ServerNet/FX2 adapter.
Dump Controller
Writes the data from the memory of the ServerNet/FX or ServerNet/FX 2 adapter field-replaceable
unit (FRU) to the file $SYSTEM.ZSERVICE.ZFOXDUMP.
The ServerNet/FX FRU must be in the Stopped state to perform this action.
External Loopback Test
Performs the external loopback firmware diagnostic test.
Before running this test, you must use the Stop action to put the ServerNet/FX or ServerNet/FX 2
adapter field-replaceable unit (FRU) in the Stopped state.
Firmware Update
Updates the firmware for a ServerNet/FX adapter (FXSA) or ServerNet/FX 2 adapter (FX2SA).
Responsive Test
Verifies that the component is installed and responding.
Set FOX Cluster Number
Sets the node to which the ServerNet/FX or ServerNet/FX2 adapter FRU is connected.
Set Left Transmitter Power Level
Sets the fiber-optic transmitter LED power for the right direction on the FOX ring.
High LED power is suitable for distances of 2 km through 4 km.
Low LED power is suitable for distances of less than 2 km.
Before setting the LED power level, you must use the Stop action to put the ServerNet/FX or
ServerNet/FX 2 adapter FRU in the Stopped state. The current power level is indicated by the Left
Transmitter Power Level attribute.
Set Right Transmitter Power Level
Sets the fiber-optic transmitter LED power for the right direction on the FOX ring.
High LED power is suitable for distances of 2 km through 4 km.
Low LED power is suitable for distances of less than 2 km.
Before setting the LED power level, you must use the Stop action to put the ServerNet/FX or
ServerNet/FX 2 adapter FRU in the Stopped state. The current power level is indicated by the Right
Transmitter Power Level attribute.