OSM Service Connection User's Guide (G06.30+)

Initialization State
The status of the storage ASIC in the CRU.
Values: Initialized, Uninitialized, Unknown
Actions
Disable ServerNet Port
Disables the specified ServerNet port on this CRU. Perform this action only as directed by OSM
alarm repair actions.
Parameter: Port Number
Enable ServerNet Port
Enables the specified ServerNet port on this CRU. Perform this action only as directed by OSM
alarm repair actions.
Parameter: Port Number
Force Power Off
This action is not supported for this CRU type. See the Prepare to Power Off action.
Power Off
This action is not supported for this CRU type. See the Prepare to Power Off action.
Prepare to Power Off
Performs precautionary check to make sure that you can safely remove the CRU.
The precautionary check makes sure that the other IOMF2 CRU in this enclosure exists and is
powered on.
If the check confirms that you can safely power off the CRU, these preparatory steps are performed:
If the SP on this IOMF2 is designated as Active (Primary), resets the SP so that the peer SP
becomes primary
Disables the battery
If the Prepare to Power Off action completes successfully, you can safely remove the CRU.
If the check fails, the Prepare to Power Off action fails, and you should perform the steps using other
OSM actions before removing the CRU.
Replace
Launches the Replace IOMF guided procedure, which provides step-by-step instructions for
replacing the IOMF2 CRU.