OSM Service Connection User's Guide (G06.30+)

Logical
Processor Access List
The currently available processors that can access the MIOE CRU.
Example: 0,1
Device State
The state of the component as known to the operating system on the server.
Values
Owning Processor
The processor to which the MIOE CRU is connected.
Example: 0
Actions
Abort
Terminates operation of the MIOE SAC. When the Abort action completes, the MIOE SAC is in the
Stopped state.
Responsive Test
Runs an online test that verifies that the MIOE SAC is integrated with the LAN subsystem, is owned,
and is in the Started state.
Start
Loads the controller operational code and starts the MIOE SAC. When the Start action finishes, the
MIOE SAC is in the Started state.
Stop
Rather than automatically stopping the MIOE SAC (as the Abort action does), this action first warns
you if the SAC is currently in use (and stops it only after you confirm).
Module
Attributes
Actions
Set Physical Location
A set of components that share a common hardware interconnection, such as a backplane. This object
applies only to Nonstop S-series processor and I/O enclosures, in which each enclosure contains
contains one group, and a group contains only one module. The module is considered a
subcomponent of the group. IOAM enclosures contain two I/O adapter modules.
Example: Module 2.1