OSM Service Connection User's Guide (G06.30+)

Replace
Launches the Replace MSEB guided procedure, which provides step-by-step instructions for
replacing the MSEB CRU.
PIC
Attributes
Actions
A replaceable component of MSEB or IOMF2 CRUs that provides connectivity to internal*
ServerNet fabrics.
* In port 6 of the MSEBs located in slot 51 and 52 of group 01 only, NNA-type ServerNet PICs can
be used to provide connectivity to external ServerNet fabrics.
Location in OSM Tree: System > Group > Module > IOMF2 > PIC
Example: PIC (1.1.52.1)
Attributes
PIC
Service State
Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK. Values
Physical
Type
Indication of the type of plug-in card.
Values: NNA, Serial Copper, ECL, Long-Haul Fiber, Short-Haul Fiber
Logical
Connector Number A unique number used to distinguish between plug-in cards on an MSEB CRU.
Actions
Clear Loopback Test
Clears the loopback test on a plug-in card (PIC). This action clears both the internal loopback test
initiated by the Internal Loopback Test action and the external loopback initiated by the guided
procedure for troubleshooting a ServerNet fabric. The action enables ServerNet ports so that packets
can be routed to the PIC from adjacent ports on the MSEB or IOMF2 and from the PIC in another
enclosure connected by the ServerNet cable to the PIC being tested. Use this action if the $ZCMOM
process terminates while a loopback test is being performed. This action is safe to use on any PIC