OSM Service Connection User's Guide (G06.30+)

Track ID
A unique serial number that identifies the component. Track IDs are used for
tracking components.
Manufacturer Identifies the manufacturer of the component.
Hardware Revision
A code that identifies the generation of the component. Hardware revision
codes are used for tracking components.
Logical
Fan Voltage The current voltage of the Fan CRU.
Main Rail Voltage
The voltage of the Main Rail, which supplies power to the CRU
from its own power supply
Disabled ServerNet Ports
Which, if any, ServerNet router ports on this CRU are disabled.
OSM actions to disable or enable a ServerNet port are performed as
directed by OSM alarm repair actions.
SCSI-Y Voltage
The voltage of the SCSI-Y path, the path configured for mirrored
disks on a system.
MOSFET Voltage
The voltage measured between the MOSFET switch and the diode to
the DCC. The MOSFET switch is located on the Other Rail between
the alternate power supply and the DCC.
Rail Minimum Voltage
The minimum voltage (39.6 volts) that must be available to power
CRU.
Main Rail Voltage After Fuse
The current voltage on the Main Rail of the PMF2 CRU, measured
after the fuse.
SCSI-X Voltage
The voltage of the SCSI-X path, the primary path used for disks on a
system.
Rail Maximum Voltage The maximum voltage limit (60 volts) for the CRU.
DCC Voltage
The operational voltage of the PMF2 CRU (specifically, the raw
voltage supplied to the DC-to-DC converters).
Other Rail Voltage
The voltage of the Other Rail, which connects the PMF2/IOMF2
CRU to the other power supply in the enclosure (to provide power in
the event of a problem with the Main Rail power supply).
Other Rail Voltage After Fuse
The current voltage on the Other Rail of the PMF2 CRU, measured
after the fuse.
Storage ASIC
Initialization State
The status of the storage ASIC in the CRU.
Values: Initialized, Uninitialized, Unknown
Actions
Disable ServerNet Port