OSM Service Connection User's Guide (G06.30+)

Disables the specified ServerNet port on this CRU. Perform this action only as directed by OSM
alarm repair actions.
Parameter: Port Number
Enable ServerNet Port
Enables the specified ServerNet port on this CRU. Perform this action only as directed by OSM
alarm repair actions.
Parameter: Port Number
Force Power Off
This action is not supported for this CRU type. See the Prepare to Power Off action.
Power Off
This action is not supported for this CRU type. See the Prepare to Power Off action.
Prepare to Power Off
Performs a precautionary check to make sure you can safely remove the CRU. This check makes
sure:
The other PMF2 CRU in this enclosure exists and is powered on
The status of the power supply for the other PMF2 CRU in this enclosure is OK
The other PMF2 CRU in this enclosure has ServerNet connectivity
The processor in the other PMF2 CRU in this enclosure has connectivity to CPU 0 or CPU 1
If the check confirms that it is safe to power off, these preparatory steps are performed:
If the SP on this PMF2 is designated as Active (Primary), resets the SP so that the peer SP
becomes primary
Disables the battery
Halts the processor on this PMF2 CRU
If the Prepare to Power Off action completes successfully, you can safely remove the CRU.
If the check fails, the Prepare to Power Off action fails, and you should perform the steps using other
OSM actions before removing the CRU.
Replace
Launches the Replace PMF guided procedure, which provides step-by-step instructions for replacing
the PMF2 CRU.
Storage ASIC Initialization Test