OSM Service Connection User's Guide (G06.30+)

Device State
The state of the CLIM as a result of the operator
command issued via OSM or SCF. Possible values
include:
Present: The CLIM is connected to at least one
ServerNet fabric.
Absent: The CLIM is not connected to either
ServerNet fabric.
Not a CLIM: A device other than a CLIM is
connected to the configured ports.
Two different CLIMs on X and Y Fabrics: Two
different CLIM devices are connected to the
ServerNet X and Y fabric ports.
Cross-Connected: The X port on the CLIM is
connected to a ServerNet Y fabric port on the
system, and/or the Y fabric port on the CLIM is
connected to a ServerNet X fabric port on the
system.
Unknown: The system is unable to determine
CLIM presence.
Down Physical Ethernet Interfaces
A list of the CLIMs physical Ethernet interfaces
which are down. The value of this attribute is None if
all physical Ethernet interfaces are up.
Presence The overall connectivity status of the CLIM.
Software Version The software version running on the CLIM.
Total Number of Physical Ethernet
Interfaces
The total number of physical Ethernet interfaces
which are configured on the CLIM.
X Fabric Connection State
The connectivity status of the CLIM to the ServerNet
X fabric. Possible values include:
Connected: The CLIM is connected to the
ServerNet X fabric.
Cross-connected: The configured ServerNet X
fabric port on the system is connected to the Y
fabric port on the CLIM.
Not Connected: The CLIM is not connected to
the ServerNet X fabric.
Not a CLIM: A device other than a CLIM is
connected to the ServerNet X fabric.
Unknown: The system is unable to determine
the X fabric connection state of the CLIM.