OSM Service Connection User's Guide (G06.30+)

Service State
Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK. Values
Physical
Hardware Revision
A code that identifies the generation of the component. Hardware revision
codes are used for tracking components.
Manufacturer Identifies the manufacturer of the component.
Part Number
The part number of the component that was assigned in manufacturing. Use
part numbers for identifying and ordering parts.
Power State Indication of whether the component is powered On or Off.
Track ID
A unique serial number that identifies the component. Track IDs are used for
tracking components.
Logical
Disabled ServerNet Ports
Which, if any, ServerNet router ports on this CRU are disabled. OSM
actions to disable or enable a ServerNet port are performed as directed by
OSM alarm repair actions.
Configured Type
The configuration type of this resource.
Value: CCSA, E4SA, FESA, G4SA, GESA, TRSA, Unknown
Device State
The state of the component as known to the operating system on the
server. Values
Actions
Abort
Terminates operation of the Ethernet 4 ServerNet Adapter (E4SA) CRU and the associated Ethernet
ServerNet addressable controller (ESAC). When the Abort action finishes, the E4SA CRU and the
ESAC are in the Stopped state.
Disable ServerNet Port
Disables the specified ServerNet router port on this CRU. Perform this action only as directed by
OSM alarm repair actions.
Parameter: Port Number
Enable ServerNet Port
Enables the specified ServerNet router port on this CRU. Perform this action only as directed by
OSM alarm repair actions.
Parameter: Port Number