OSM Service Connection User's Guide (G06.32+)

Power Supply (FCDM)
Subcomponent of a FCDM. There are two power supplies in each FCDM.
Location in OSM Tree: System > Group > FCDM Collection > FCDM > Power Supply
Example: Power Supply (111.211.1.95)
Attributes
Power Supply
Displayed in the Attributes tab and Attributes dialog box only if the value is something
other than OK. Values
Service State
Physical
Indicates whether or not the power supplys (amber) fault LED is blinking.
Value: Blinking or Off
LED State
The vendor hardware type.Type
Logical
Whether the power source is On or Off.AC Power State
The state of the component as known to the operating system on the server. ValuesDevice State
A code that identifies the generation of the component provided by its supplier.Vendor Hardware Revision
Actions
Blink LED Off
Turns off the blinking of the power supplys (amber) fault LED.
SCF Equivalent: SCF Control SAC $ZZSTO.#sac-name, deviceid(shelf,bay), LED OFF
Blink LED On
Causes the power supplys (amber) fault LED to blink on and off.
SCF Equivalent: SCF Control SAC $ZZSTO.#sac-name, deviceid(shelf,bay), LED ON
Replace
Displays the procedure for replacing the power supply.
176 System Resources