Power Supply (Disk Drive Enclosure)
Attributes
Actions
Subcomponent of a Disk Drive Enclosure. There are two power supplies in each enclosure.
Location in OSM Tree: System > Group > Daisy Chained Disk Drive Enclosure > Disk Drive
Enclosure > Power Supply
Example: Power Supply (111.211.1.95)
Attributes
Power Supply
Service State
Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK. Values
Physical
Part Number
The part number of the component that was assigned in manufacturing. Use
part numbers for identifying and ordering parts.
LED State
Indicates whether or not the power supplys (amber) fault LED is blinking.
Value: Blinking or Off
Hardware Revision
A code that identifies the generation of the component. Hardware revision
codes are used for tracking components.
Type The vendor hardware type.
Logical
Vendor Hardware Revision
A code that identifies the generation of the component provided by its
supplier.
AC Power State Whether the power source is On or Off.
Device State
The state of the component as known to the operating system on the
server. Values
Actions
Blink LED Off
Turns off the blinking of the power supplys (amber) fault LED.
SCF Equivalent: SCF ALTER SWITCH $ZZSMN, NEAREST { X | Y}, BLINK NONE