Hardware Freeze Flag
Whether the processor has been frozen by a hardware
error:
True: A hardware error in this processor caused it to
freeze. (Disregard the Halt Code and Lites Register
values.)
False: This processor has not experienced a freeze caused
by a hardware error.
Unknown: Hardware freeze state could not be read.
Online Boot Millicode Firmware
Online Boot Millicode Firmware Update is not supported for processors in S7000 PMF CRUs or on
systems running G06.11 or earlier. The related attributes and action are not displayed for processors
on which this action is not supported.
Default File Name The name of the file to be used for the Boot Millicode firmware update.
Running Version The version of the Boot Millicode currently running on the processor.
Default File Version
The version of the firmware to be used for the Boot Millicode firmware
update.
Compare State
The differences, if any, between the running and default firmware versions.
Values
Actions
Disable Processor Freeze
Turns off the Freeze Enable flag on this processor. A freeze-disabled processor both:
Participates in a system freeze only when the processor itself halts●
Is unaffected when any other processor halts or the system Freeze action is performed●
Halt
Terminates all processes running on this processor. Halting a processor does not affect any other
processors in the system.
Caution: Halting a processor might result in unrecoverable loss of data. Use the Halt action only
to prepare for reloading the processor or for performing a memory dump.
Online Boot Millicode Firmware Update
Updates the Boot Millicode firmware running on the processor.
Online Boot Millicode Firmware Update is not supported for processors in S7000 PMF CRUs or on
systems running G06.11 or older. The related attributes and action will not be displayed for