Default File Version
The version of the firmware to be used for a (boot) Firmware Update.
Compare State
The differences, if any, between the current and default boot firmware
versions. Values
Actions
Abort
Terminates operation of the ServerNet Adapter ServerNet addressable controller. When the Abort
action finishes, the SAC is in the Stopped state.
Firmware Update
Updates the boot firmware for the adapter SAC.
Responsive Test
Runs an online test that verifies the SAC is integrated with the LAN subsystem, is owned, and is in
the Started state.
Start
Loads the controller operational code and starts the ServerNet addressable controller. The SAC must
be in the Stopped state before you perform this action. When the Start action completes, the SAC is
in the Started state.
Stop
Rather than automatically stopping the SAC (as the Abort action does), this action first warns you if
the SAC is currently in use (and stops it only after you confirm).
Test Verify
Runs the power-on self-test for the SAC component of the CRU. To perform this action, the CRU
must be in the Started state, and the SAC component must be in the Stopped or Diagnose state.
SCSI Controller
Attributes
Actions
A controller that manages devices using the Small Computer System Interface (SCSI) protocol. This
SCSI controller is a component of Processor Multifunction (PMF) CRUs and I/O Multifunction
(IOMF) CRUs.
Location in OSM Tree: System > Group > Module > PMF2 > SCSI Controller