OSM User's Guide (G06.27+)
Table Of Contents
- OSM User's Guide
- OSM User's Guide
- What's New in This Guide
- About This Guide
- Related Reading
- Chapter 1. Introducing OSM
- Chapter 2. Preparing the OSM Environment
- Chapter 3. Configuring OSM
- Chapter 4. Starting the OSM Service Connection
- Chapter 5. Using the Management Window
- Chapter 6. Viewing Alarms
- Chapter 7. Viewing Attributes
- Chapter 8. Performing Actions
- Chapter 9. Viewing Summary Reports
- Chapter 10. Managing a System
- Chapter 11. System Resources
- Chapter 12. Managing a ServerNet Cluster
- Chapter 13. Cluster Resources
- Chapter 14. Updating ServerNet Cluster Topology
- Glossary
- Index
- Legal Notice
- Version and Copyright Information

LED State
Indicates whether or not the blowers (amber) fault LED is blinking.
Value: Blinking or Off
Hardware Revision
A code that identifies the generation of the component. Hardware revision
codes are used for tracking components.
Type The vendor hardware type.
Logical
Device State
The state of the component as known to the operating system on the server. Values
Actions
Blink LED Off
Turns off the blinking of the blowers (amber) fault LED.
SCF Equivalent: SCF ALTER SWITCH $ZZSMN, NEAREST { X | Y}, BLINK NONE
Blink LED On
Causes the blowers (amber) fault LED to blink on and off.
SCF Equivalent: SCF ALTER SWITCH $ZZSMN, NEAREST { X | Y}, BLINK ALL
Replace
Displays the procedure for replacing the blower.
CCSA (Common Communication ServerNet
Adapter)
Attributes
Actions
An adapter that allows PCI-based communications devices to connect to a server. A CCSA CRU can
hold up to four CCSA ServerNet addressable controllers (SACs) with four ports each, providing up
to 16 links per adapter.
Location in OSM Tree: System > Group > Module > CCSA
Example: CCSA $ZZLAN.CCSA1 (2.1.53)