OSM User's Guide (G06.27+)

LED State
Indicates whether or not the blowers (amber) fault LED is blinking.
Value: Blinking or Off
Hardware Revision
A code that identifies the generation of the component. Hardware revision
codes are used for tracking components.
Type The vendor hardware type.
Logical
Device State
The state of the component as known to the operating system on the server. Values
Actions
Blink LED Off
Turns off the blinking of the blowers (amber) fault LED.
SCF Equivalent: SCF ALTER SWITCH $ZZSMN, NEAREST { X | Y}, BLINK NONE
Blink LED On
Causes the blowers (amber) fault LED to blink on and off.
SCF Equivalent: SCF ALTER SWITCH $ZZSMN, NEAREST { X | Y}, BLINK ALL
Replace
Displays the procedure for replacing the blower.
CCSA (Common Communication ServerNet
Adapter)
Attributes
Actions
An adapter that allows PCI-based communications devices to connect to a server. A CCSA CRU can
hold up to four CCSA ServerNet addressable controllers (SACs) with four ports each, providing up
to 16 links per adapter.
Location in OSM Tree: System > Group > Module > CCSA
Example: CCSA $ZZLAN.CCSA1 (2.1.53)