OSM User's Guide (G06.28+)

Updates the SCSI Boot Code firmware for a single service processor (SP).
Available only for SPs on PMF and PMF2 CRUs.
Optional Parameter: File Namefile name of the boot code file on the local node.
Syntax: $volume.subvolume
Default value: $SYSTEM.SYSnn
SP Firmware Update
Updates the firmware for a single service processor (SP).
Optional Parameter: File Name -- the name of the firmware file.
Syntax: $volume.subvolume
Default value: $SYSTEM.SYSnn
SNDA (ServerNet/DA)
Attributes
Actions
The ServerNet/DA CRU (customer-replaceable unit) is an adapter that allows external storage
devices to be connected to servers. The external storage devices are physically connected to either
Fiber SACs (FSAC) or SCSI SACs (SSAC) mounted on the ServerNet/DA CRU.
Location in OSM Tree: System > Group > Module > SNDA
Slot Location: ServerNet/DA CRUs can be located in slots 53 and 54 in processor enclosures
(service side) or in slots 51, 52, 53, and 54 in I/O enclosures (service side).
Example: SNDA (12.1.54)
Attributes
SNDA
Service State
Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK. Values
Physical
Hardware Revision
A code that identifies the generation of the component. Hardware revision
codes are used for tracking components.
Manufacturer Identifies the manufacturer of the component.