OVNM 5.3 - Operations Agent for NonStop Installation Guide
Appendix A: Installation Information 114
15. OVNM Home Terminal
Select either a physical hometerm or a process that will be
continuously available.
Default: $ZHOME
16. OVNM Process Prefix
A two character prefix that will be used as the first two
characters for all the OVNM processes, making them unique
The first character must be a letter, and both characters should
be alphanumeric.
Example: If you specify the prefix as OV, then the Elink process
will be called $OVELK.
17. OVNM Work Subvolume
The subvolume where the OVNM installation files will be copied.
Default: $SYSTEM.ZOVNM
18. OVNM Port
Port number for Elink connection with the HP NonStop system
Default: 5030
19. OVNM Subvolume
The subvolume where OVNM will be installed
Default: $SYSTEM.OVNM
20. Log to Collector
The collector where the application will log all events
Default: $0
21. Priority
Priority of the main OVNM process
Default: 160
22. Alive Message Interval
The time interval after which Host components send an Alive
message to the front-end. This is specified in minutes.
Default: 0
23. Primary CPU
Primary CPU for the main OVNM process
Default: 0
24. Backup CPU
Backup CPU for the main OVNM process
Default: 1
25. OVNM Distributors, Collectors and Filters
The OVNM distributor to be used along with the associated
Collectors and Filters
26. OCC Port
This port will be used by the OCC application.
Default: 5020
27. OCC Distributors, Collectors and Filters
The distributor to be used along with the associated
Collectors and Filters by the OCC application