OVNM 5.3 - Operations Agent for NonStop Object Configuration Client Guide
Object Configuration Client Interface  18 
NOTE:
 In the previous OVNM versions, when you used the Object Configuration Client to turn Node 
Monitoring OFF
, the OVNM application would continue to consume EMS messages and react to them (if they 
were defined in an EMS threshold) and send them to 
HPOM (if specified). With OVNM release 4.8, when 
you use the Object Configuration Clien
t to turn monitoring off/on for the entire node, you have the option of 
having this impact the EMS traffic as well. For details on how to enable the feature, refer to 
Customizing Node 
Monitoring Feature
 topic in OVNM User and Installation Guide. 
•  Activate Config Monitoring 
This option is used to activate monitoring for the selected threshold configuration(s). It activates monitoring 
for all the objects under the selected threshold(s), which are flagged for active monitoring. This option is 
enabled only if monitoring is inactive for the selected threshold(s). 
•  Inactivate Config Monitoring 
This option is used to inactivate monitoring for the selected threshold configuration(s) only. It inactivates 
monitoring for all the objects under the selected threshold(s), which are flagged for active monitoring. This 
option is enabled only if monitoring is active for the selected threshold(s). 
•  Activate Object Monitoring 
Clicking this option activates monitoring for the selected object(s) in the Objects pane. This option is 
enabled only if the monitoring for the selected object(s) is inactive. 
•  Inactivate Object Monitoring 
Clicking this option inactivates monitoring for the selected object(s) in the Objects pane. This option is 
enabled only if the monitoring for the selected object(s) is active. 
2-6-5 Recovery Menu 
The various options available in the Recovery menu are: 
•  Activate Config Recovery 
•  Inactivate Config Recovery 
•  Activate Object Recovery 
•  Inactivate Object Recovery 
Figure 2-12 OCC Recovery Menu 
The various options available in the Recovery menu are: 
•  Activate Config Recovery 
This option is used to activate recovery for the selected threshold configuration(s). It activates recovery for 
all the objects under the selected threshold(s) for which recovery has been configured. This option is 
enabled only if recovery has been configured but inactive for the selected threshold(s). 
•  Inactivate Config Recovery 
This option is used to inactivate recovery for the selected threshold configuration(s). It inactivates recovery 
for all the objects under the selected threshold(s) for which recovery has been configured. This option is 
enabled only if recovery has been configured and active for the selected threshold(s). 
•  Activate Object Recovery 
This option is used to activate recovery for the selected object(s). This option is enabled only if recovery has 
been configured but inactive for the selected threshold(s). 
•  Inactivate Object Recovery 
This option is used to inactivate recovery for the selected object(s). This option is enabled only if recovery 