OVNM 5.3 - Operations Agent for NonStop Object Configuration Client Guide
Appendix B: EMS Message Handling 83
Figure B-6 OCC Threshold Dialog Box with Event Number Information
7. Select the threshold violation criteria using The object is in violation, if box. Other fields in the Threshold
area get activated depending on the selected violation criteria.
Figure B-7 OCC Threshold Dialog Box with Threshold Information
The EMS Object provides several Threshold options. If you are not familiar with EMS Tokens then it is
recommended that you select either EXECUTE-DEFINED-ACTION or EVENT TEXT.
• EXECUTE-DEFINED ACTIONS
This threshold type is used when you do not need any additional qualification on the EMS event – when
Owner.Subsystem and event number provide enough information to identify the EMS event message
you want to process. After selecting the option, click the Action button to define the action to be taken.
• EMPHASIS-TOKEN-TRUE
This threshold is used when SSID and Event are all that are needed to identify the correct EMS message
and you want only those events that contain an Emphasis Token that has a true value. SSID can support
* in subsystem portion. For example: TANDEM.*.