OVNM 5.3 - Operations Agent for NonStop Object Reference Guide
Threshold Policies 182  
Policy 
Description 
Operators Allowed 
024:MSGS-RCVD-IOAIN-
UNK-SRVR 
This threshold type allows the user to check the 
number of messages the IOAIN process received 
that contained a destination server class that is not 
the server class for an SS7 Management process 
or the SS7 Router process. 
•  Equal to <value1> 
•  Not equal to <value1> 
•  Less than <value1> 
•  Less than or equal to <value1> 
•  Greater than <value1> 
•  Greater than or equal to <value1> 
•  Greater than <value1> and less than 
<value2>  
•  Less than <value1> or greater than 
<value2> 
025:SS7_SEND-ERRS 
This threshold type allows the user to check the 
number of messages the IOAIN process 
encountered that resulted in a Message Transfer 
System (MTS) error. 
•  Equal to <value1> 
•  Not equal to <value1> 
•  Less than <value1> 
•  Less than or equal to <value1> 
•  Greater than <value1> 
•  Greater than or equal to <value1> 
•  Greater than <value1> and less than 
<value2>  
•  Less than <value1> or greater than 
<value2> 
026:INV-CLIENT-MSG 
This threshold type allows the user to check the 
number of messages the IOAIN process received 
from IOAIN processes in other CPUs that were 
invalid. 
•  Equal to <value1> 
•  Not equal to <value1> 
•  Less than <value1> 
•  Less than or equal to <value1> 
•  Greater than <value1> 
•  Greater than or equal to <value1> 
•  Greater than <value1> and less than 
<value2>  
•  Less than <value1> or greater than 
<value2> 
027:MSGS-UNK-ORIG-SRV-
CLASS 
This threshold type allows the user to check the 
number of messages the IOAOUT process 
received that contained an originating server class 
that is not the server class for an SS7 
Management process or the SS7 Router process. 
•  Equal to <value1> 
•  Not equal to <value1> 
•  Less than <value1> 
•  Less than or equal to <value1> 
•  Greater than <value1> 
•  Greater than or equal to <value1> 
•  Greater than <value1> and less than 
<value2>  
•  Less than <value1> or greater than 
<value2> 
029:INV-MSG-FROM-DLC-BY-
IOAIN 
This threshold type allows the user to check the 
number of messages the IOAIN process received 
from one or more DLCs that had an invalid 
message number. 
•  Equal to <value1> 
•  Not equal to <value1> 
•  Less than <value1> 
•  Less than or equal to <value1> 
•  Greater than <value1> 
•  Greater than or equal to <value1> 
•  Greater than <value1> and less than 
<value2>  
•  Less than <value1> or greater than 
<value2> 
030:IOAIN-MATE-FAILURES 
This threshold type allows the user to check the 
number of times the IOAIN process detected that 
its mate (in another CPU) has failed. 
•  Equal to <value1> 
•  Not equal to <value1> 
•  Less than <value1> 
•  Less than or equal to <value1> 
•  Greater than <value1> 
•  Greater than or equal to <value1> 
•  Greater than <value1> and less than 
<value2>  
•  Less than <value1> or greater than 
<value2> 