OVNM 5.3 - Operations Agent for NonStop SNMP Adapter Guide

Displaying Events on BMC Event Browser 32
Enter CEF Field name for SubSysNum (Enter for 'nomap') ====>2
When asked for a CEF Field, you may either enter the CEF Field number from
the provided list or type the CEF Field name.
1 OriginDateTime 2 OriginClass 3 Origin 4 OriginKey
5 OriginEventClass 6 OriginSeverity 7 DomainClass 8 Domain
9 ObjectClass 10 Object 11 ObjectLocation 12 ObjectStaff
13 ITMgmtLayer 14 Service 15 Customer 16 ITMgmtProcess
17 ITMgmtProcessState 18 ParameterName 19 ParameterValue 20
FreeText
Enter CEF Field name for Subject (Enter for 'nomap') ====>8
When asked for a CEF Field, you may either enter the CEF Field number from
the provided list or type the CEF Field name.
1 OriginDateTime 2 OriginClass 3 Origin 4 OriginKey
5 OriginEventClass 6 OriginSeverity 7 DomainClass 8 Domain
9 ObjectClass 10 Object 11 ObjectLocation 12 ObjectStaff
13 ITMgmtLayer 14 Service 15 Customer 16 ITMgmtProcess
17 ITMgmtProcessState 18 ParameterName 19 ParameterValue 20
FreeText
Enter CEF Field name for ToolID (Enter for 'nomap') ====>
For each possible value of Severity, enter 'value <space> PATROL EM Severity
word'.
If the value of Severity contains spaces, enclose the value in double quotes
(e.g. "ALARM IS SERIOUS").
For example: ====>4 Critical
Enter 'Done' when finished
PATROL EM Severities are:
Critical
Major
Minor
Warning
Informational
Clear
1 Informational
2 Warning
3 Minor
4 Major
5 Critical
Done
Displaying Events on BMC
Event Browser