OVNM 5.3 - Operations Agent for NonStop Troubleshooting Guide
Host Installation Client: Errors & Warnings 38
Table 2-9 During NonStop Node Installation
Sr.No. Error Message and Warning
9.
Possible Causes: The OVNM Host Response for Installation dialog box shows the error code “10053” when the
connection was aborted possibly due to a data transmission timeout or protocol error.
Action to be taken: Make sure that the connectivity between the NonStop Server and workstation where Host
Installation Client is installed is not broken during OVNM installation. You will have to reinstall OVNM.
10.
Possible Causes: The OVNM Host Response for Installation dialog box shows the error “TIMEOUT IN RECV OR
ACCEPT” when the transaction was aborted because it exceeded the AUTOABORT timeout duration.
Action to be taken: Make sure that the connectivity between the NonStop Server and workstation where Host
Installation Client is installed is not broken during OVNM installation. You will have to reinstall OVNM.