OVNM 5.3 - Operations Agent for NonStop Troubleshooting Guide
Host Management Client: Errors & Warnings 66
Table 3-7 Generating Test Message on NonStop Server
Sr.No. Error Message and Warning
2.
Possible Causes: The OVNM Host Response for Generating Test Message dialog box shows the error “Expecting
the name of an existing file” when the Host Management Client is unable to find GENEMS in the
specified location.
Action to be taken: To run the GENEMS utility, it should be available in the volume.subvolume where OVNM is
installed. Switch to the volume.subvolume where OVNM has been installed and check whether the GENEMS
utility exists.
3.
Possible Causes: The OVNM Host Response for Generating Test Message dialog box shows the error “Unable to
connect to \NODE” when the connectivity between the NonStop Server and the workstation where Host
Management Client is installed was broken at some point during the generation of test message.
Action to be taken: Make sure that the connectivity between the NonStop Server and workstation where Host
Management Client is installed is not broken during running the Test Message utility.