OVNM 5.3 - Operations Agent for NonStop Troubleshooting Guide

OCC: Errors and Warnings 81
Some of the fields available in the Object Details section are different for ATP6100, BASE24, EMS, OSS,
PROCESS and TCPIP subsystems. The different error messages and warnings displayed when creating threshold
configurations for these subsystems, their causes and the actions to be taken are described below:
4-2-7-1 ATP6100
Table 4-7 ATP6100 Subsystem
Sr.No. Error Message and Warning
1.
Possible Causes: This message box is displayed when the Line field available in the Object Details section for the
ATP6100 subsystem is left blank. This field is activated when you select SU as the Object Type.
Action to be taken: Specify the name of the line under which SU’s are defined in the Line field. You can either type
in the line name or select from the list of the entries already made.
2.
Possible Causes: This message box is displayed when the SU field available in the Object Details section for the
ATP6100 subsystem is left blank. This field is activated when you select SU as the Object Type.
Action to be taken: Specify a valid SU object name in the SU field. You can either type in the name or select from
the list of the entries already made. This field allows * wildcard character.
4-2-7-2 BASE24
Table 4-8 BASE24 Subsystem
Sr.No. Error Message and Warning
1.
Possible Causes: This message box is displayed when the Resource Node field available in the Object Details
section for the BASE24 subsystem is left blank.
Action to be taken: Specify the resource node in the Resource Node field. You can either type in the line name or
select from the list of the entries already made. This field accepts wildcard characters.
OCC: Errors and Warnings