PAM Configuration and Management Manual
PAM Configuration and Management Manual—523349-003
B-1
B SCF Command Summary
ABORT [ /OUT file-spec/ ] LINE line-name 
 [ , SUB [ ALL | NONE | ONLY ] ] [, SEL [NOT] state ]
ABORT [ /OUT file-spec/ ] MSAP msap-name 
 [ , SUB [ ALL | NONE | ONLY ] ] [, SEL [NOT] state ]
ABORT [ /OUT file-spec/ ] PORT port-name 
 [, SEL [NOT] state ]
ABORT [ /OUT file-spec/ ] PROCESS process-name 
ADD [ /OUT file-spec/ ] PORT port-name 
 {, ADDRESS port-address }
 {, TYPE { ETHERNET | LLC1 } }
 [, DATAFORWARDCOUNT integer ]
 [, DATAFORWARDTIME { timevalue | INFINITE } ]
 [, DELIVERYMODE { SERIAL | PARALLEL } ]
 [, GROUPMACADDRESS { macaddress | DEFAULT } ]
 [, REQUESTSIZE integer ]
 [, LLC2ENABLED ]
ALTER [ /OUT file-spec/ ] MSAP msap-name 
 , MAXPORTS integer 