STATS MSAP Command
The STATS MSAP command returns statistical information about an MSAP object.
When the RESET option is used, the statistics counters reset to 0. The STATS MSAP
command becomes a sensitive command when the RESET option is specified. You
must have the SUPER ID to reset the counters.
Command Syntax
OUT file-spec
directs any SCF output generated for this command to the specified file.
MSAP msap-name
is the name of the MSAP.
Consideration
There are no considerations for this command.
Example
This example returns statistics for the MSAP:
-> STATS MSAP $LAN24.#SNATR
STATS MSAP Display
Sample Time
indicates the beginning of the sample period.
Reset Time
is the time when the counters were last reset.
Open SAP Reqs Recvd
is the number of requests received from SNAX to open a SAP.
STATS [ /OUT file-spec/ ] MSAP msap-name
[ , RESET ]
PAM Stats MSAP $LAN24.#SNATR
Sample Time..... 11 Nov 1997, 10:00:15.392
Reset Time...... 10 Nov 1997, 18:14:22.240
Open SAP Reqs Recvd.... 0D Open SAP Reqs Rejected..... 0D
Close SAP Reqs Recvd... 0D Close SAP Reqs Rejected.... 0D
Memory Alloc Fails..... 0D