208: ZPAM-EVT-IO-PROC-ABENDED
ZPAM-VAL-ABEND-CONFIG-ERR
System configuration error.
ZPAM-VAL-ABEND-FUNC-NOT-IMP
The PAM process entered into an unexpected function.
ZPAM-VAL-ABEND-NSK-PROC-ERR
The PAM process received an unexpected error from an NSK function call.
ZPAM-VAL-ABEND-INTERNAL-ERR
The PAM process received an unexpected internal error.
ZPAM-VAL-ABEND-CONFIG-LIF-ERR
The associated LIF specified in PAM startup does not exist or returned an error. 
Restart PAM with the correct LIF name. Check the status of the LIF and 
associated PIF/SAC in the SLSA subsystem, correct the SLSA problem and 
restart the PAM process.
ZPAM-VAL-ABEND-LIF-NO-P-ACC
The PAM process does not have potential access to the LIF from either the 
primary or the backup processor. Check the status of the LIF and associated 
PIF/SAC in the SLSA subsystem. You either need to bring up PAM on the 
processors that have access to the LIF or change the SLSA configuration so that 
the processors in which you intend to bring up PAM have potential access.
ZPAM-VAL-ABEND-CONFIG-LIF-NO-D-ACC
The PAM process does not have data access to the LIF from either the primary 
or the backup processor. Check the status of the LIF and associated PIF/SAC in 
the SLSA subsystem. You either need to bring up PAM on the processors that 
have access to the LIF or change the SLSA configuration so that the processors 
in which you intend to bring up PAM have potential access.
ZPAM-VAL-ABEND-CONFIG-ARG-FEW
Not enough arguments were specified while starting up PAM. For example, the 
associated LIF name was not specified. Restart PAM with all the required 
arguments.
ZPAM-VAL-ABEND-CONFIG-ARG-INV
An invalid argument was specified while starting up PAM. Restart PAM with 
the correct value for the arguments.