Pathmaker Messages Manual

Pathmaker Messages
067870 Tandem Computers Incorporated 2–111
Invalid Request code
Cause. The new process server received a request that did not have the correct
REQUEST^CODE (101) in the first byte.
Issued by the Pathmaker product.
Effect. New process startup fails.
Recovery. Check the version of the new process requester installed in the Pathmaker
release subvolume. If it is the same as the version of the Pathmaker product, note the
error message and contact your Tandem representative.
Invalid Request length
Cause. The new process server received a request which had an input buffer length
different from a new process request.
Issued by the Pathmaker product.
Effect. New process startup fails.
Recovery. Check the version levels of Pathmaker object programs and contact your
Tandem support group.
Invalid request name:
invalid-name
Cause. In the IPC Definition screen you attempted to enter in the Request Reference
Object field an invalid reply name, or the reply name is a COBOL reserved word.
Issued by the Pathmaker product.
Effect. The operation is not performed.
Recovery. Reenter a valid request name and retry the operation.
The Request Reference Object field must contain an existing DDL definition, DDL
record, NonStop SQL table object name, or a valid alias name.