Pathmaker Messages Manual
Pathmaker Messages
067870 Tandem Computers Incorporated 2–123
Keys cannot be updated in views
Cause. You attempted to update a key by using a view.
Issued by the generated application.
Effect. Operation fails.
Recovery. To update a key value, access the base table containing the key column.
Library conflict:
new-process-name
Cause. A shared program-file does not have the same library configuration for all
users.
Issued by the Pathmaker product.
Effect. New Process startup fails.
Recovery. Make sure all library configurations are consistent. Refer to the
NEWPROCESS discussion in the Guardian Procedure Calls Reference Manual.
Link denied; Send to
server-class
Cause. Your request to the PATHMON for a link to the server class has been denied
for indeterminate reasons, and the TCP has no previously established links to the class.
SEND error issued by the generated application.
Effect. Operation fails.
Recovery. . Retry the operation. If you cannot establish a link, contact the Pathmaker
project administrator.
Link field appears in an OCCURS item:
qualified-field-name
Cause. You specified a link field that is in a group with multiple occurrences.
Issued by the Pathmaker product and by PMADL.
Effect. Requester generation fails.
Recovery. Remove the OCCURS clause from the group and regenerate.