Pathmaker Messages Manual

Pathmaker Messages
067870 Tandem Computers Incorporated 2–165
OPEN Process-Config file: error 12.
Cause. Harmony cannot access the new process configuration file, DICTNPC;
Harmony must open DICTNPC on the project catalog subvolume to guide new
process creation. Error 12 indicates that another user opened DICTNPC with exclusive
access.
Issued by the Pathmaker product.
Effect. Pathmaker startup fails.
Recovery. Ask the other user to close DICTNPC and reopen it with shared access. You
can use the FUP LISTOPENS command to determine who opened the file.
Operation canceled because of BREAK
Cause. You stopped the PMPROJECT utility by pressing the BREAK key.
Issued by PMPROJECT.
Effect. The PMPROJECT utility ends.
Recovery. Purge any files created by the PMPROJECT utility.
Operation is allowed only in interactive input
Cause. You specified an operation in a PMADL source file, but the operation can only
be performed when PMADL is accepting input from a terminal or process.
Issued by PMADL.
Effect. The interactive operation is ignored.
Recovery. Remove the operation command from the source file.
Operation is not allowed on Pathmaker-defined object —
object-
name
Cause. You specified an object predefined by Pathmaker in a statement which cannot
be used to access Pathmaker-defined objects, or you attempted to define an object
whose name starts with the prefix reserved by Pathmaker, "T9154-".
Issued by PMADL.
Effect. The reference to the Pathmaker-defined object is ignored. PMADL continues
with the next object specified, if any.
Recovery. Correct the object name.