Parameter type clash, formal
local-name
of
action-object
Cause. You specified formal and actual parameters that are of incompatible types.
Issued by the Pathmaker product and by PMADL.
Effect. Requester generation fails.
Recovery. Change one of the parameter lists so that the reference objects are of
compatible data types.
CALL parameters are matched to formal parameters specified on the Requester
Parameters screen of the called requester.
SEND parameters are matched to formal parameters specified on the IPC Definition
screen of the service.
Parent Instance should not have repetition:
parent-instance-
name
Cause. You specified more than one repetition for this parent instance; only leaf nodes
in a DB requester can have repetition.
Issued by the Pathmaker product and by PMADL.
Effect. Requester generation fails.
Recovery. Change the number of repetitions to one or delete the child record.
Parent link field required — please enter name
Cause. You attempted to update the Record Instance Detail screen for this record with
a child field name but no parent field name.
Issued by the Pathmaker product.
Effect. Add or update fails.