2–178 067870 Tandem Computers Incorporated
Program error: Corrupt data file info.
Cause. The request to the standard server contains incorrect information about a data
file that was previously opened successfully by the same requester.
Issued by the generated application.
Effect. Operation fails.
Recovery. Contact your Tandem representative.
Program is not configured —
new-process
Cause. The named program is not included in the DICTNPC file for new process
configuration.
Issued by the Pathmaker product.
Effect. New process startup fails.
Recovery. Check the configuration and correct the file, then retry the operation.
Program Logic Error
Cause. A Logic Error has occurred, and it is not one of those with an I/O status value
in the range of 40 to 49.
Server error issued by the generated application.
Effect. Program aborts after execution of any applicable declarative statement.
Recovery. Debug service code logic and retry the operation.
Project home terminal is no longer valid —
project name
Cause. The home terminal of the project you are starting no longer exists on the local
system. This error may occur if the terminal was removed from the system's
configuration after the project was added or if the terminal is a Local Area Network
(LAN) session.
Issued by PMPROJECT.
Effect. PMPROJECT skips the indicated project and continues with the next project.
Recovery. Use PMPROJECT ALTER to change the project's home terminal, then
reconfigure and cold start the project.