067870 Tandem Computers Incorporated 2–181
Project or catalog was opened for read-only access
Cause. You attempted to perform an operation on a Pathmaker object description, that
modifies the currently open catalog, such as compiling a PMADL object description,
but the current catalog was opened for read-only access.
Issued by PMADL.
Effect. The operation is ignored.
Recovery. Open the catalog for read-write access using the ?PROJECT or ?CATALOG
commands without the READ option.
Project security violation —
name
Cause. You attempted to alter, convert, delete, reconfigure, shut down, or start a
project that you are not authorized to access with these commands. Only the owner of
a project or SUPER.SUPER can alter, delete, or shut down a project. Only the owner
can convert, reconfigure, or start a project.
Issued by PMPROJECT.
Effect. PMPROJECT skipped the indicated project and continued with the next project.
Recovery. Have the owner of the project or SUPER.SUPER execute the command for
you.
Protection View only contains a syskey:
table name
Cause. In a DB requester, a protection view is referenced that contains only a syskey.
Issued by the Pathmaker product.
Effect. Requester generation fails.
Recovery. Change the reference object or add another column to the protection view.