Pathmaker Messages Manual

Pathmaker Messages
2–184 067870 Tandem Computers Incorporated
Pseudofield not allowed in the request copy of column
Cause. You attempted to enter a pseudofield into the Copy Of column of the IPC
Definition screen for a request message.
Issued by the Pathmaker product.
Effect. Update fails.
Recovery. Remove the pseudofield from the Copy Of column and press F2 to update
the screen.
Pseudofield overlaps a
screen-element
at
location
Cause. You attempted to define a pseudofield on, or move a pseudofield to, a
previously defined screen element.
Issued by the Pathmaker product and by PMADL.
Effect. Operation canceled.
Recovery. Delete the screen element or choose a different location for the pseudofield.
Pseudofield param mismatch, formal
parameter-name
Cause. You matched a pseudofield to either a different pseudofield or to a reference
object that is not a pseudofield. This condition is normally detected when you update
the SEND Parameter Definition screen.
Issued by the Pathmaker product and by PMADL.
Effect. Requester generation fails.
Recovery. Note this error message and contact your Tandem representative.
Pseudofield starts at an invalid screen location —
location
Cause. You attempted to define a pseudofield on, or move a pseudofield to, an invalid
screen location. Invalid positions are:
Any location outside the screen
Location (1,1), the uppermost-left screen position
Issued by the Pathmaker product and by PMADL.
Effect. Operation canceled.