Pathmaker Messages Manual
Pathmaker Messages
2–238 067870 Tandem Computers Incorporated
Subvolume name is not properly qualified —
subvolume
Cause. You specified a partially qualified subvolume name in the installation
configuration file supplied to PMINSTAL.
Issued by PMINSTAL.
Effect. The illegal subvolume name was ignored. PMINSTAL terminated after reading
the installation configuration file.
Recovery. Correct the installation configuration file.
Syntax error (
explanation)
Cause. You supplied a command containing a syntax error to PMPROJECT or
PMINSTAL.
Issued by PMPROJECT and PMINSTAL.
Effect. Operation canceled. The correct syntax for the command is displayed following
the error message.
Recovery. Correct the command and rerun PMPROJECT.
Syntax error (
explanation)
Cause. PMADL detected a syntax error in a statement or command. The
explanation indicates what kind of text PMADL was expecting when it
encountered the error.
Issued by PMADL.
Effect. PMADL ignores the invalid part of the statement or command. If the statement
is an ADL object description, the description is not stored in the current catalog.
Recovery. Correct the statement or command. The syntax for PMADL is described in
the Pathmaker Reference Manual.