Pathmaker Messages Manual
Pathmaker Messages
067870 Tandem Computers Incorporated 2–267
Unable to select FILLER, LEVEL-88, or redefined field
Cause. You attempted to select and return FILLER, LEVEL-88, or redefined field from
the Reference Field Value List screen.
Issued by the Pathmaker product.
Effect. Select fails.
Recovery. Choose another field to select and return.
Unable to send startup message —
new-process
Cause. The named process will not accept the startup message.
Issued by the Pathmaker product.
Effect. The process abended because of CPU or program failure.
Recovery. Check the configuration and the security of the object file.
Unable to send to PATHMON process, error:
error code
Cause. The Pathmaker program encountered a file system error when attempting to
send a request to run the Pathmaker user interface to the project's PATHMON process.
Effect. Pathmaker startup fails.
Recovery. Correct the condition indicated by the error. If necessary, contact your
system manager.
Unable to specify nonindex reads for DDL records
Cause. You have the Nonindex Reads field set to
Y
.
Issued by the Pathmaker product.
Effect. Update fails.
Recovery. Reset the Nonindex Reads field to
N
and retry the update. Refer to the
Pathmaker Reference Manual for more details about this field.