Pathmaker Messages Manual
Pathmaker Messages
067870 Tandem Computers Incorporated 2–269
Unaudited catalogs cannot be opened for read/write access
Cause. You attempted to open a Pathmaker catalog for read-write access, but the
catalog is not audited by the TMF software. The Pathmaker program requires that
catalogs which may be updated be audited by the TMF software.
Issued by PMADL.
Effect. The previously opened catalog, if any, is closed and no new catalog is opened.
Recovery. Alter the catalog files using the FUP ALTER command to enable TMF
auditing.
Undefined column
Cause. A column name you specified does not exist in the referenced table.
Effect. Operation fails.
Recovery. Enter the name of a column from the referenced table and repeat the
operation.
Undefined Error Code
Cause. An undocumented file error code has been returned by the COBOL run-time
routines.
Server error issued by the generated application.
Effect. Operation fails.
Recovery. Contact your Tandem representative.
Undefined send error; Send to
server-class
Cause. SEND error issued by the generated application.
Effect. SEND fails.
Recovery. Check PATHLOG for the SEND error; determine if the error is appropriate
for a more recent version of Pathway.