Pathmaker Messages
067870 Tandem Computers Incorporated 2–19
Boxes nested too deeply to display any item
Cause. The child record boxes are so numerous that data cannot be displayed in the
paging area.
Issued by the Pathmaker product and by PMADL.
Effect. Default screen generation fails.
Recovery. Remove at least one level of box nesting.
Call loop detected; initial action suppressed
Cause. The Initial Actions in two requesters form a loop. A loop is formed when a
requester calls another requester through an Initial Action, and the second requester
calls the first requester through its Initial Action.
Issued by the Pathmaker product during simulation.
Effect. The Initial Action is not performed.
Recovery. Correct the Initial Actions to avoid looping.
CALL parameter not found
Cause. The Pathmaker program could not find a CALL parameter while attempting to
rematch the CALL parameter list with the formal parameters specified in the
Requester Parameter screen.
Issued by the Pathmaker product.
Effect. Rematch fails.
Recovery. Press F4 to list the current CALL parameters. If the problem persists, contact
your Tandem representative.