Pathmaker Messages Manual

Pathmaker Messages
2–272 067870 Tandem Computers Incorporated
Unique key field is not on screen:
qualified-field-name
Cause. You specified that a unique key for this DB requester should not be displayed
on the application screen; a unique key is either a primary key or a unique alternate
key. The database service Insert is enabled.
Issued by the Pathmaker product and by PMADL.
Effect. Requester generation fails.
Recovery. Include the unique key on the application screen by adding it to the Display
Field List (if the requester uses the default screen) or by adding it through the Screen
Painter, or change the value of Insert on the Record Instance Detail screen to
N
.
Unknown DEFINE propagation error
num
:
new-process-name
Cause. A DEFINE propagation error was returned from a version of later than the
current version.
Issued by the Pathmaker product.
Effect. New Process startup fails.
Recovery. Look up the error number (
num
) in the most recent version of the Guardian
Procedure Calls Reference Manual.
Unknown error —
new-process
Cause. A new process error was returned from a more recent version of the Tandem
NonStop Kernel than the version that was current when the current error list was
created. The last number serviced is 15.
Issued by the Pathmaker product.
Effect. New process startup fails.
Recovery. Refer to the Guardian Procedure Errors and Messages Manual for details about
new process errors.