Pathmaker Messages Manual

Pathmaker Messages
2–274 067870 Tandem Computers Incorporated
Unsupported object version:
SQL-table name
Cause. You requested an SQL table or view with a version number greater than the
currently supported version.
Issued by the generated application.
Effect. Table or view access fails.
Recovery. Preferably, do not access that table or view. However, if you must access the
table or view, first install a later version of the Pathmaker product.
Unsupported Pathmaker catalog version —
file name
Cause. The catalog you specified in a ?CATALOG or ?PROJECT command is not a D20
Pathmaker catalog, and therefore cannot be accessed by D20 PMADL.
The
file name
indicates a file in the catalog.
Issued by PMADL.
Effect. The previously opened catalog, if any, is closed and no new catalog is opened.
Recovery. Use the correct version of PMADL to access the catalog, or convert the
catalog to D20 Pathmaker.
Unsupported request message format
Cause. The Screen Painter server did not recognize the message sent to it by the Screen
Painter requester.
Issued by the Pathmaker product.
Effect. The Screen Painter session abended.
Recovery. Ensure that the requester and server are of compatible releases. If they are,
and the problem persists, contact your Tandem representative.