Pathmaker Messages Manual
Pathmaker Messages
2–24 067870 Tandem Computers Incorporated
Cannot communicate with system monitor —
new-process
Cause. The system monitor will not start the new process, perhaps because of system
loading.
Issued by the Pathmaker product.
Effect. New process startup fails.
Recovery. Try again or contact your system manager. Refer to the Guardian Procedure
Errors and Messages Manual for information about new process errors.
Cannot convert projects from this release —
release
Cause. You ran the D20 Pathmaker version of the PMPROJECT CONVERT command,
but the only other version of the Pathmaker product installed on your system is B41 or
C00. D20 PMPROJECT can only convert projects from C20 Pathmaker or later.
Issued by PMPROJECT.
Effect. The PMPROJECT CONVERT command is canceled.
Recovery. Install a version of the Pathmaker product between C20 and D10, and use it
to convert the B41/C00 projects. Then convert the projects to D20 using the D20
PMPROJECT CONVERT command.
Cannot create access paths for SQL Table —
table object name
Cause. PMPROJECT CONVERT encountered an error while attempting to create
default access paths for an SQL Table registered in the project being converted.
Issued by PMPROJECT.
Effect. PMPROJECT continues to convert the catalog. No access paths are defined for
the indicated SQL Table.
Recovery. If desired, create the default access paths manually by using the SQL Table
Registration screen in the Pathmaker block-mode user interface.
Cannot FETCH on this Access Path:
access-path-name
Cause. Not all of the required parameters were specified.
Effect. Generation fails.
Recovery. Specify all of the required parameters.