Pathmaker Messages Manual
Pathmaker Messages
2–30 067870 Tandem Computers Incorporated
Catalog was opened without a project name
Cause. You attempted to perform an operation that requires a project name, such as
generating a Pathmaker requester, service, or server, but the current catalog was
opened using the ?CATALOG command, which does not indicate a project name.
Issued by PMADL.
Effect. The operation is ignored.
Recovery. Open the catalog using the ?PROJECT command.
Catalog was updated by someone else since your last update
Cause. Another user edited this application screen after the start of the current session
or after the project catalog was last updated.
Issued by the Pathmaker product.
Effect. The Screen Painter session abended. Any changes made since the last project
catalog update were lost.
Recovery. Ensure that only one user edits a given screen at a time.
Child link field required — please enter name
Cause. You attempted to update the Record Instance Detail screen for this record with
a parent field but no child field name.
Issued by the Pathmaker product.
Effect. Update fails.
Recovery. Supply a child field name or remove the parent field name.
Column is already in this path.
Cause. A column name cannot appear more than once in an access path.
Effect. Operation fails.
Recovery. Remove the column name from the screen and repeat the operation.