Pathmaker Messages Manual

Pathmaker Messages
067870 Tandem Computers Incorporated 2–49
Display detail listed; default screen picture has been
shortened
Cause. The default screen picture shown in the Display Detail screen has been
shortened because the field length has been changed in the Screen Painter.
Issued by the Pathmaker product.
Effect. New default screen picture displayed.
Recovery. No recovery needed. This is an advisory message.
Display field is already defined
Cause. A field in a reference object is used to define more than one display field in a
requester description.
Issued by PMADL.
Effect. The requester description is not stored in the catalog.
Recovery. Remove the duplicate display field, or use a different reference object field.
Display field list has changed in the meantime — try F4
Cause. Another user updated the Display Field List since you first listed the screen.
Issued by the Pathmaker product.
Effect. Action fails.
Recovery. Press F4 to relist the screen, then retry the action.
Display field list internal logic error — contact support
Cause. The Pathmaker program encountered an internal error.
Issued by the Pathmaker product.
Effect. Pathmaker might display unexpected data on the screen.
Recovery. Make a note of this error and contact Tandem support.