067870 Tandem Computers Incorporated 2–75
Help text already defined for screen field —
field-name
Cause. The screen field was already defined in the input file of a HELPUTIL UPDATE
operation.
Issued by HELPUTIL.
Effect. The requester was not updated in the help database.
Recovery. Correct the input file.
Help text line exceeds 79 characters
Cause. A line of text in the source file is too long to store in the HELP database.
Issued by HELPUTIL.
Effect. The line is ignored and the current requester is not updated.
Recovery. Shorten the line of text in the source file and retry the operation.
Identifier exceeds the maximum length allowed in this context
Cause. A name is too long to be a legal Pathmaker, Pathway, or SQL identifier.
Issued by PMADL.
Effect. The object description containing the invalid name is not stored in the current
catalog.
Recovery. Correct the name.
I/O error
err-num
to home terminal:
new-process-name
Cause. The new process has undefined externals and the message cannot be displayed
on the home terminal due to an operating system error.
Issued by the Pathmaker product.
Effect. New Process startup fails.
Recovery. Run the new process from the command interpreter to determine the
undefined externals.